Skip to main content

Effective Dose Calculations and Dose Rate Distribution Around Z-Portal Passenger Security Screening

  • Conference paper
  • First Online:
International Conference for Innovation in Biomedical Engineering and Life Sciences (ICIBEL 2015)

Part of the book series: IFMBE Proceedings ((IFMBE,volume 56))

  • 1638 Accesses

Abstract

Due to the increased concern over terrorist attacks, new technologies have been developed to improve the efficiency of security screening of passengers. The Z – portal is an inspection system designed to scan vehicles and large trucks, buses, and cargo containers. It has been installed in many sites in Egypt. The passenger should be screened before allowing to pass from a land to another. This technology uses ionizing radiation (X-rays). As the hazards related to ionizing radiation include the well-known carcinogenic risk, as well as other health effects, assessment of public exposure to these new types of security screening of a great importance we are presenting an assessment and distribution mapping of dose rate around two portals, then effective dose calculations and statistical analysis was performed. Methods: Two Z-portal systems are used for screening passenger by vehicles and trucks; Measurement of radiation dose rate was performed using dose rate survey meter, exposed with the two units during ten consecutive exposures each the organ effective doses was calculated. Results: Effective radiation doses ranged between 0.41 µSv and 6.66 µSv for one exposure. Thyroid, bone marrow, colon, lung, stomach, breast absorbed the most radiation for both screening systems with p <0.001. Conclusions: Effective doses of organ screened by the transmission system is significantly higher than the backscatter system however both systems are exceeding the dose limit of the general public per scan, as per ANSI standards of 0.1 µSv per scan for individual, cumulative effect is not considered, both systems should be reevaluated based on the general principles of justification, optimization and dose limitation versus new screening technology like passive millimeter – wave with no radiation emission.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. I. Farrag .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Farrag, S.I. (2016). Effective Dose Calculations and Dose Rate Distribution Around Z-Portal Passenger Security Screening. In: Ibrahim, F., Usman, J., Mohktar, M., Ahmad, M. (eds) International Conference for Innovation in Biomedical Engineering and Life Sciences . ICIBEL 2015. IFMBE Proceedings, vol 56. Springer, Singapore. https://doi.org/10.1007/978-981-10-0266-3_48

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-0266-3_48

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-0265-6

  • Online ISBN: 978-981-10-0266-3

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics